Chlor Alkali Cells 3.276m2

Chlor Alkali Cells 3.276m2

1. Cell element:2402mm × 1562mm ×42mm
2. Effective Area:3.276m2
3. Cell Voltage:5.5kA/m2
4. Cell voltage ≤2.98V

Product Introduction

Introduction

The structure design for Chlor alkali cells 3.276m2 is more reasonable, more adapted to high current density operation. It lowered the power consumption, improved the high current density operation, reduced the structure voltage, improved outlet structure, reduced leakage current, improved cell's rigidity. Our 3.276m2 Chlor alkali cells Anode halfshell sealing surface use Ti / Pd plate and have good corrosion resistance. And our 3.276m2 Chlor alkali cells Cathode halfshell use a new cathode mattress to improve the cathode mesh surface installation mode. Changsheng Chlor alkali cells can replace BiTAC electrolyzer partially or wholly. In another words, it can be mixed and run with BiTAC/N-BiTAC cell at same electrolyzer

Main Technical characteristics

Unit cell size2402mm * 1562mm * 42mm
Effective Area3.276M2
Designed Operation Current13.1 ~ 18.2kA (Current Density: 4.0-5.56 kA/m2 )
Expected Power consumption

5.5kA/m2,power consumption ≤ 2050kwh/t

(on a 100% caustic soda basis)

Cell current5.5kA/m2
Cell voltage≤2.98V
SEP Value

Cathode Coating SEP Value: ≤ 1.25V (current density:4000 A/m2,

calomel electrode: Vs.SEP, Temperature:( 90 ± 1)℃ ) ;

Anode Coating SCE Value:≤ 1.12V (current density: 4000A/m2,

calomel electrode: Vs.SEP,saturated brine,Temperature: ( 95 ±2) ℃ )

Design Feature

1. Changsheng company has more scientific design of anode internal circulation structure

2. It has excellent electrical conductivity .

3. Excellent gas-liquid separate structure and outlet liquid

4. Changsheng 3.276m2 Chlor alkali cells is more excellent rigid

5. Lower current leakage (with internal insert PFA feed distributor tube)

6. Excellent installation for Cathode structure and surface mesh

7. It can replace Bitac element partially or wholly. In another word, it can be mixed and run with BiTAC electrolyzer cell together.

We company also can provide zero-gap cells which can well replace the AKC. UHDE and NBZ cells, this Chlor-alkali electrolyzer 3.276m2 related accessories such as Rubber sheet, Teflon plate, Hose gasket, Hose, Bracket, Positioning pin, Wrench, Inlet&outlet header, Frame. etc all can be provided.

The related nickel/titanium pipe, pipe fittings, plate, and copper busbar also can be provided. Welcome inquiry!