Tubular Titanium MMO Anode

Tubular Titanium MMO Anode

Application:Buried with Coke breeze backfill
Anode Material:Titanium substrate (ASTM B338) coated with Mixed Metal Oxide
MMO:Coating
Thickness:Minimum 6.0 micron (coating weight min. 20 gram / m2)
Coating:Consumption Rate:Max 1 mg / Amp year Required Anode Cur. Density:100 Amps/m2 (at soil + coke breeze)
Anode Current Output:8.0 Amps / pcs for 30 years
Anode Dimension:Diameter 25.4 mm x 1000 mmmm, nominal surface area: 80mm2
Life time:30 years (at current output max 8.0 Amps)

Product Introduction

Tubular Titanium MMO Anode

It is a type of anode used in electrochemical processes, typically for the production of chlorine or caustic soda. It is made of titanium and is coated with a mixed metal oxide (MMO) material.Since 2001, Changsheng Titanium has started to export the tubular titanium MMO anode supply. It has a history of more than 20 years.


Tubular Titanium MMO Anode can be utilized as helper anodes for applied ebb and flow cathodic security in seawater, freshwater, soil and cement natural media. Homegrown and unfamiliar cathodic insurance designing practice shows that this new anode material enjoys numerous extraordinary benefits. However, when using MMO coated titanium anodes, the following considerations must be made to ensure a sufficient level of protection:


(1) The formulation of the MMO coating ought to be reasonably selected in accordance with the protective environment.


(2) When making an MMO coated titanium anode, strict quality control should be done on things like the coating thickness, uniformity, and bonding between the coating and the titanium substrate, among other things. ought to meet specific necessities to guarantee the best anode execution.


(3) To prevent moisture intrusion, the MMO coated titanium anode and wire connection should have low resistance and good watertightness.


(4) The wire ought to resist corrosion and provide effective insulation.


DATA SHEET of ICCP ANODE

1

General Data

1.1

Equipment Tag

GB-001

1.2

Anode Groundbed

Quantity

1

1.3

Equipment Name

Anode Groundbed

1.4

Specification No.

26076-850-3PS-GEE-00001 Specification of Cathodic

Protection for Onshore Buried Pipeline (Amendment)

1.5

Drawing No.

26076-850-EQZ-GEE-00009 Auxiliary Anode Groundbeds

Installation Details (Unloading Facilities)

1.6

Code & Standard

NACE SP0572 Design, Installation, Operation, and Maintenance of Impressed Current Deep Groundbed

2

Environment Data

2.1

Location

Onshore / Buried

2.2

Ambient Temperature

(℃)

Min. : 21.5 Max. : 36.7

2.3

Ambient Relative

Humidity (%)

Min.: 40 Max. : 75

2.4

Design Life

30 years

2.5

Linepipe Size

1000mm/1220mm/1500mm

2.6

Service

Crude oil

2.7

Area Classification

Non Hazardous

3

Anode

3.1

Anode type

String Tubular Titanium / MMO anode

3.2

Application

Buried with Coke breeze backfill

3.3

Anode Material

Titanium substrate (ASTM B338) coated with Mixed Metal

Oxide

3.4

Method of Coating

Thermal Decomposition

3.5

MMO Coating

Thickness

Minimum 6.0 micron (coating weight min. 20 gram / m2)

3.6

Coating Consumption

Rate

Max 1 mg / Amp year

3.7

Required Anode Cur.

Density

100 Amps/m2 (at soil + coke breeze)

3.8

Anode Current Output

8.0 Amps / pcs for 30 years

3.9

Anode Dimension

Diameter 25.4 mm x 1000 mm, nominal surface area is 0.08m2


3.10

Life time

30 years (at current output max 8.0 Amps)

3.11

Anode Cable

20m / 18m /16m long 25 mm2 PVDF / HMWPE cable tails for anodes at different depth

3.12

Type of Cable Anode Joint

Center connection, crimped + moisture seal

3.13

Anode Arrangement

Single vertical anode

3.14

Quantity

3 anodes / groundbed (HOLD)

4

Inspection & Testing

4.1






Inspection & Testing (Note 3)

Chemical Analysis of Titanium

4.2

X-Ray Test of Anode Coating

4.3

Anode to Cable Sealing Test

4.4

Pull out Strength Tests Report of Cable-Anode Connection

4.5

Anode to Cable Resistance Test

4.

Bend and MMO Coating Peel Off Test

4.7

Acid test of Pin Hole

5

Deep Well Casing Pipe

5.1

Material

Carbon Steel pipe

5.2

Dimension

Diameter 8" x 6 m long

5.3

Total Length / Quantity

Minimum 16 m per groundbed (HOLD)

6

Backfill

6.1

Material

Calcined Petroleum Coke

6.2

Fixed Carbon

Min 99%

6.3

Particle Size

Avg. 0-5 mm

6.4

Resistivity (dry)

Max. 5 ohm-cm

6.5

Consumtion Rate

Max. 0.5 kg/Amps-yr

6.6

Fixed Carbon

Min 99%

6.7

Dry Bulk density

800-900 kg/m3

6.8

Quantity

300 kg/groundbed

7

Deep well Accessories



7.1

Cover

PVC pipe 10" x 1 meter + PVC Caps 10"

7.2

Venting

Perforated PVC Pipe 3/4" class AW + PVC Tee

7.3

Anode Centralizer

Bolted steel clamp-four legs for 1" anode x 8" pipe casing. 2

ea/anode

7.4

Cable Protector

Flexible PVC Conduit dia 50 mm

7.5

Hanger

Stainless steel 316 pipe, diameter 25mm x 300 mm with

cable clamp

Application Case

Tubular titanium MMO (Mixed Metal Oxide) anodes are commonly used in a variety of applications where corrosion protection is critical, such as in the cathodic protection of steel structures, pipelines, and storage tanks in the marine, offshore, and industrial sectors.

One example of the application is in the protection of underground pipelines used for the transportation of petroleum products, natural gas, or water. In these applications, the anodes are installed along the length of the pipeline and connected to a DC power source. The anodes work by providing a cathodic current that counteracts the natural tendency of the steel pipeline to corrode in the soil environment. By supplying electrons to the pipeline, the anodes protect it from corrosion and extend its service life.

Another example of the use of it is in the protection of reinforced concrete structures such as bridges, parking garages, and buildings. In these applications, the anodes are embedded in the concrete and connected to a power source. The anodes work by providing a protective current that counteracts the natural tendency of steel reinforcing bars to corrode in the presence of moisture and chloride ions. By supplying a protective current, the anodes prevent corrosion and extend the service life of the concrete structure.

Hot Tags: mmo tubular anode;Tubular Titanium MMO Anode supply

You Might Also Like

(0/10)

clearall